Others ELISA Kits

Goat MDA(Malondialdehyde) ELISA Kit

Product No

FY-EGoat1348

Sample Type

serum, plasma and other biological fluids

Assay Time

1.5H

Price($)

Size

Purchase details

Contact supplier to negotiate price details

100% Quality Assurance

Fast Shipping

Product Details
Product Name in English:
Goat MDA(Malondialdehyde) ELISA Kit
Species:
Goat
Alternative Name:
Malondialdehyde; MDA
Assay Type:
Competitive
Standard:
1000 pg/mL
Sensitivity:
5.39 pg/mL
Detection Range:
15.63-1000 pg/mL
Assay Time:
1.5H
Sample Type:
serum, plasma and other biological fluids
Research:
Metabolic pathway;Hepatology;Hormone metabolism;
Test Principle:
This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with MDA protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to MDA. Next,Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of stop solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of MDA in the samples is then determined by comparing the OD of the samples to the standard curve.
Technical Data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.
Concentration OD1 OD2 Average OD Corrected
1000 0.27 0.271 0.271
500 0.37 0.372 0.371
250 0.564 0.565 0.565
125 0.825 0.828 0.827
62.5 1.12 1.122 1.121
31.25 1.515 1.527 1.521
15.63 1.829 1.834 1.832
0 2.493 2.506 2.5
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level were tested on 3 different plates, 20 replicates in each plate, respectively.
Item Intra-assay Precision Intra-assay Precision
Sample 3 3
Replicate 9 18
CV(%) 5 8
Rate of recovery
The recovery of spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type Range(%) Average Recovery(%)
Serum (n=8) 90-105 97
EDTA plasma (n=8) 88-102 95
Cell culture media (n=8) 87-97 90
Linear
Samples were spiked with high concentrations of target proteins and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Serum (n=5) EDTA plasma (n=5) Cell culture media (n=5)
1:2 Range (%) 92-105 89-98 92-103
Average (%) 97 94 94
1:4 Range (%) 92-101 89-98 86-97
Average (%) 100 94 87
1:8 Range (%) 80-94 81-94 83-96
Average (%) 85 91 85
1:16 Range (%) 86-101 96-105 91-103
Average (%) 89 104 99
Assay Procedures
Related literature
Related Products