Mouse ELISA Kits

Mouse GROβ/CXCL2(Growth Regulated Oncogene Beta) ELISA Kit
Copy Product Information

Product No

FY-EM5138

Sample Type

Serum, Plasma, Tissue homogenate and Other biological samples;Sample Volume=100μL

Assay Time

3.5H

Price($)

Size

Purchase details

Contact supplier to negotiate price details

100% Quality Assurance

Fast Shipping

Product Details
Product Name in English:
Mouse GROβ/CXCL2(Growth Regulated Oncogene Beta) ELISA Kit
Species:
Mouse
Alternative Name:
chemokine (C-X-C motif) ligand 2; CINC-2a; CINC3; CINC-3; C-X-C Motif Chemokine 2; CXCL2; GRO beta; GRO2 oncogene; GRO2; GROB; Gro-beta; Growth-regulated protein beta; Macrophage inflammatory protein 2-alpha; melanoma growth stimulatory activity beta; MGSA beta; MGSA-b; MGSA-beta; MIP2; MIP-2; MIP2A; MIP-2a; MIP2-alpha; SCYB2
Uniport ID:
P10889
Assay Type:
Sandwich
Standard:
20pg/mL
Sensitivity:
2.36 pg/mL
Detection Range:
0.31-20pg/mL
Assay Time:
3.5H
Sample Type:
Serum, Plasma, Tissue homogenate and Other biological samples;Sample Volume=100μL
Test Principle:
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to GROβ/CXCL2. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to GROβ/CXCL2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain GROβ/CXCL2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of GROβ/CXCL2 in the samples is then determined by comparing the OD of the samples to the standard curve.
Technical Data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.
Concentration OD1 OD2 Average OD Corrected
20 2.331 2.353 2.342 2.284
10 1.537 1.545 1.541 1.49
5 0.906 0.907 0.907 0.859
2.5 0.423 0.426 0.425 0.376
1.25 0.244 0.245 0.245 0.197
0.63 0.144 0.145 0.145 0.097
0.31 0.097 0.097 0.097 0.05
0 0.047 0.047 0.047 0
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level were tested on 3 different plates, 20 replicates in each plate, respectively.
Item Intra-assay Precision Intra-assay Precision
Sample 3 3
Replicate 9 18
CV(%) 5 8
Rate of recovery
The recovery of spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type Range(%) Average Recovery(%)
Serum (n=8) 86-99 92
EDTA plasma (n=8) 80-95 87
Cell culture media (n=8) 80-95 87
Linear
Samples were spiked with high concentrations of target proteins and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Serum (n=5) EDTA plasma (n=5) Cell culture media (n=5)
1:2 Range (%) 86-102 98-105 91-102
Average (%) 92 100 92
1:4 Range (%) 87-96 92-101 86-102
Average (%) 95 93 94
1:8 Range (%) 89-98 85-105 87-99
Average (%) 95 99 97
1:16 Range (%) 83-103 87-98 99-105
Average (%) 90 92 102
Assay Procedures