Mouse ELISA Kits

Mouse Ang-Ⅰ(Angiotensin Ⅰ) ELISA Kit
Copy Product Information

Product No

FY-EM4708

Sample Type

Serum, Plasma, Tissue homogenate and Other biological samples

Assay Time

1.5H

Price($)

Size

Purchase details

Contact supplier to negotiate price details

100% Quality Assurance

Fast Shipping

Product Details
Product Name in English:
Mouse Ang-Ⅰ(Angiotensin Ⅰ) ELISA Kit
Species:
Mouse
Alternative Name:
Angiotensin-1
Uniport ID:
P11859(25~34aa)
Assay Type:
Competitive
Standard:
1000pg/mL
Sensitivity:
9.38 pg/mL
Detection Range:
15.63-1000pg/mL
Assay Time:
1.5H
Sample Type:
Serum, Plasma, Tissue homogenate and Other biological samples
Research:
Neuro science;Hormone metabolism;
Test Principle:
This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Ang-Ⅰ protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Ang-Ⅰ. Next,Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of stop solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Ang-Ⅰ in the samples is then determined by comparing the OD of the samples to the standard curve.
Technical Data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.
Concentration OD1 OD2 Average OD Corrected
1000 0.279 0.282 0.281
500 0.379 0.379 0.379
250 0.573 0.576 0.575
125 0.834 0.836 0.835
62.5 1.129 1.135 1.132
31.25 1.524 1.534 1.529
15.63 1.838 1.839 1.839
0 2.502 2.508 2.505
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level were tested on 3 different plates, 20 replicates in each plate, respectively.
Item Intra-assay Precision Intra-assay Precision
Sample 3 3
Replicate 9 18
CV(%) 5 8
Rate of recovery
The recovery of spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type Range(%) Average Recovery(%)
Serum (n=8) 96-109 102
EDTA plasma (n=8) 81-95 88
Cell culture media (n=8) 85-97 91
Linear
Samples were spiked with high concentrations of target proteins and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Serum (n=5) EDTA plasma (n=5) Cell culture media (n=5)
1:2 Range (%) 86-97 95-102 91-102
Average (%) 95 101 97
1:4 Range (%) 83-96 95-102 89-99
Average (%) 84 97 92
1:8 Range (%) 91-103 98-106 88-104
Average (%) 103 101 102
1:16 Range (%) 96-105 87-98 84-98
Average (%) 100 90 98
Assay Procedures
Related literature
Related Products