EasyPro Series ELISA Kits

EasyPro Mouse Heme Oxygenase 1(HO1)ELISA Kit

Product No

FY-EM2276S

Sample Type

Serum, Plasma, Tissue homogenate and Other biological samples;Sample Volume=50uL

Assay Time

1.5H

Price($)

Size

Purchase details

Contact supplier to negotiate price details

100% Quality Assurance

Fast Shipping

Product Details
Product Name in English:
EasyPro Mouse Heme Oxygenase 1(HO1)ELISA Kit
Species:
Mouse
Alternative Name:
HO1, HSP32, Bk286b1
Uniport ID:
P14901
Assay Type:
Sandwich
Standard:
4000pg/mL
Sensitivity:
37.5 pg/mL
Detection Range:
62.5-4000pg/mL
Assay Time:
1.5H
Sample Type:
Serum, Plasma, Tissue homogenate and Other biological samples;Sample Volume=50uL
Research:
Cardiovascular biology
Test Principle:
This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to HO1. Samples (or Standards) and and Horseradish Peroxidase (HRP) linked antibody specific for HO1 are added to the micro ELISA plate wells. HO1 in samples (or standards) combines with the coated antibody and HRP linked detection antibody special to HO1. Excess conjugate and unbound sample or standard are washed from the plate. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm. The OD value is proportional to the concentration of HO1. You can calculate the concentration of HO1 in the samples by comparing the OD of the samples to the standard curve.
Technical Data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.
Concentration OD1 OD2 Average OD Corrected
4000 2.392 2.429 2.411 2.353
2000 1.552 1.579 1.566 1.508
1000 0.878 0.886 0.882 0.824
500 0.478 0.483 0.481 0.423
250 0.258 0.262 0.26 0.202
125 0.155 0.156 0.156 0.098
62.5 0.108 0.108 0.108 0.05
0 0.058 0.058 0.058 0
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level were tested on 3 different plates, 20 replicates in each plate, respectively.
Item Intra-assay Precision Intra-assay Precision
Sample 3 3
Replicate 9 18
CV(%) 5 8
Rate of recovery
The recovery of spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type Range(%) Average Recovery(%)
Serum (n=8) 82-94 88
EDTA plasma (n=8) 94-105 98
Cell culture media (n=8) 83-97 91
Linear
Samples were spiked with high concentrations of target proteins and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Serum (n=5) EDTA plasma (n=5) Cell culture media (n=5)
1:2 Range (%) 90-99 93-102 87-98
Average (%) 98 97 89
1:4 Range (%) 82-101 93-106 83-94
Average (%) 97 97 89
1:8 Range (%) 93-105 87-101 85-98
Average (%) 101 101 94
1:16 Range (%) 87-103 91-104 85-97
Average (%) 90 94 95
Assay Procedures
Related literature
Related Products