EasyPro Series ELISA Kits

EasyPro Human MIγ/CXCL9(Monocyte Interferon Gamma Inducing Factor) ELISA Kit
Copy Product Information

Product No

FY-EH2783S

Sample Type

Serum, Plasma, Tissue homogenate and Other biological samples;Sample Volume=50uL

Assay Time

1.5H

Price($)

Size

Purchase details

Contact supplier to negotiate price details

100% Quality Assurance

Fast Shipping

Product Details
Product Name in English:
EasyPro Human MIγ/CXCL9(Monocyte Interferon Gamma Inducing Factor) ELISA Kit
Species:
Human
Alternative Name:
Chemokine(C-X-C motif) ligand 9,CXCL9, Monokine induced by gamma interferon,MIG,CMK, Humig, SCYB9, crg-1
Uniport ID:
Q07325
Assay Type:
Sandwich
Standard:
1000pg/mL
Sensitivity:
9.38 pg/mL
Detection Range:
15.63-1000pg/mL
Assay Time:
1.5H
Sample Type:
Serum, Plasma, Tissue homogenate and Other biological samples;Sample Volume=50uL
Research:
Signal transduction;
Test Principle:
This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to MIγ/CXCL9. Samples (or Standards) and and Horseradish Peroxidase (HRP) linked antibody specific for MIγ/CXCL9 are added to the micro ELISA plate wells. MIγ/CXCL9 in samples (or standards) combines with the coated antibody and HRP linked detection antibody special to MIγ/CXCL9. Excess conjugate and unbound sample or standard are washed from the plate. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm. The OD value is proportional to the concentration of MIγ/CXCL9. You can calculate the concentration of MIγ/CXCL9 in the samples by comparing the OD of the samples to the standard curve.
Technical Data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.
Concentration OD1 OD2 Average OD Corrected
1000 2.477 2.485 2.481 2.433
500 1.597 1.629 1.613 1.565
250 0.904 0.92 0.912 0.864
125 0.469 0.474 0.472 0.424
62.5 0.26 0.261 0.261 0.213
31.25 0.154 0.156 0.155 0.107
15.63 0.103 0.103 0.103 0.055
0 0.047 0.048 0.048 0
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level were tested on 3 different plates, 20 replicates in each plate, respectively.
Item Intra-assay Precision Intra-assay Precision
Sample 3 3
Replicate 9 18
CV(%) 5 8
Rate of recovery
The recovery of spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type Range(%) Average Recovery(%)
Serum (n=8) 87-99 93
EDTA plasma (n=8) 82-94 88
Cell culture media (n=8) 97-107 102
Linear
Samples were spiked with high concentrations of target proteins and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Serum (n=5) EDTA plasma (n=5) Cell culture media (n=5)
1:2 Range (%) 87-98 83-98 87-96
Average (%) 91 96 94
1:4 Range (%) 85-96 92-103 86-98
Average (%) 86 93 96
1:8 Range (%) 92-102 86-97 91-103
Average (%) 97 92 98
1:16 Range (%) 81-93 93-101 87-90
Average (%) 84 100 89
Assay Procedures
Related literature