EasyPro Series ELISA Kits

EasyPro Universal 8-Epi Prostaglandin F2 Alpha(8-epi-PGF2a)ELISA Kit

Product No

FY-EU10107S

Sample Type

serum, plasma and other biological fluids

Assay Time

45min

Price($)

Size

Purchase details

Contact supplier to negotiate price details

100% Quality Assurance

Fast Shipping

Product Details
Product Name in English:
EasyPro Universal 8-Epi Prostaglandin F2 Alpha(8-epi-PGF2a)ELISA Kit
Species:
Universal
Alternative Name:
8-EpiPGF2-α; 8epi-PGF2a
Assay Type:
Competitive
Standard:
2000pg/mL
Sensitivity:
9.55 pg/mL
Detection Range:
31.25-2000 pg/mL
Assay Time:
45min
Sample Type:
serum, plasma and other biological fluids
Research:
Endocrinology;Pulmonology;Hepatology;Hormone metabolism;
Test Principle:
This ELISA kit uses the Competitive-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with 8-epi-PGF2a Samples (or Standards) and Horseradish Peroxidase (HRP) linked antibody specific for 8-epi-PGF2a are added to the micro ELISA plate wells. 8-epi-PGF2a in samples (or standards) competes with a fixed amount of 8-epi-PGF2a on the solid phase supporter for sites on the HRP linked detection antibody specific to 8-epi-PGF2a. Excess conjugate and unbound sample or standard are washed from the plate. The substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450±2 nm. The concentration of 8-epi-PGF2a in the samples is then determined by comparing the OD of the samples to the standard curve.
Technical Data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.
Concentration OD1 OD2 Average OD Corrected
2000 0.195 0.197 0.196
1000 0.331 0.333 0.332
500 0.546 0.553 0.55
250 0.88 0.882 0.881
125 1.308 1.334 1.321
62.5 1.7 1.717 1.709
31.25 2.076 2.086 2.081
0 2.516 2.534 2.525
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level were tested on 3 different plates, 20 replicates in each plate, respectively.
Item Intra-assay Precision Intra-assay Precision
Sample 3 3
Replicate 9 18
CV(%) 5 8
Rate of recovery
The recovery of spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type Range(%) Average Recovery(%)
Serum (n=8) 95-107 101
EDTA plasma (n=8) 90-105 97
Cell culture media (n=8) 80-90 84
Linear
Samples were spiked with high concentrations of target proteins and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Serum (n=5) EDTA plasma (n=5) Cell culture media (n=5)
1:2 Range (%) 80-92 82-93 85-97
Average (%) 84 87 94
1:4 Range (%) 86-102 82-93 95-104
Average (%) 101 88 99
1:8 Range (%) 87-103 96-105 82-93
Average (%) 102 104 85
1:16 Range (%) 85-101 87-98 81-96
Average (%) 87 87 87
Assay Procedures
Related literature
Related Products