Rat ELISA Kits

Rat NOX1(Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1) ELISA Kit
Copy Product Information

Product No

FY-ER5684

Sample Type

Serum, Plasma, Tissue homogenate and Other biological samples

Assay Time

3.5H

Price($)

Size

Purchase details

Contact supplier to negotiate price details

100% Quality Assurance

Fast Shipping

Product Details
Product Name in English:
Rat NOX1(Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1) ELISA Kit
Species:
Rat
Alternative Name:
NADPH oxidase 1, NOX-1, Mitogenic oxidase 1, MOX-1, NADH/NADPH mitogenic oxidase subunit P65-MOX, NOH-1 , Nox1, Mox1, Noh1
Uniport ID:
Q9WV87
Assay Type:
Sandwich
Standard:
20ng/mL
Sensitivity:
0.19 ng/mL
Detection Range:
0.32-20ng/mL
Assay Time:
3.5H
Sample Type:
Serum, Plasma, Tissue homogenate and Other biological samples
Research:
Signal transduction;Metabolic pathway;Tumor immunity;Infection immunity;Developmental science;
Test Principle:
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to NOX 1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to NOX 1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain NOX 1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of NOX 1 in the samples is then determined by comparing the OD of the samples to the standard curve.
Technical Data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.
Concentration OD1 OD2 Average OD Corrected
20 2.311 2.319 2.315 2.284
10 1.517 1.53 1.524 1.49
5 0.886 0.893 0.89 0.859
2.5 0.403 0.406 0.405 0.376
1.25 0.224 0.225 0.225 0.197
0.63 0.124 0.125 0.125 0.097
0.32 0.077 0.078 0.078 0.05
0 0.027 0.027 0.027 0
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level were tested on 3 different plates, 20 replicates in each plate, respectively.
Item Intra-assay Precision Intra-assay Precision
Sample 3 3
Replicate 9 18
CV(%) 5 8
Rate of recovery
The recovery of spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type Range(%) Average Recovery(%)
Serum (n=8) 80-95 86
EDTA plasma (n=8) 94-105 98
Cell culture media (n=8) 85-97 91
Linear
Samples were spiked with high concentrations of target proteins and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Serum (n=5) EDTA plasma (n=5) Cell culture media (n=5)
1:2 Range (%) 95-104 83-95 86-102
Average (%) 98 86 95
1:4 Range (%) 93-105 88-102 87-103
Average (%) 104 101 97
1:8 Range (%) 82-101 85-97 85-101
Average (%) 87 89 85
1:16 Range (%) 91-103 80-92 81-99
Average (%) 97 85 97
Assay Procedures
Related literature
Related Products