Rat ELISA Kits

Rat FNDC5(Fibronectin type Ⅲ domain-containing protein 5) ELISA Kit
Copy Product Information

Product No

FY-ER5215

Sample Type

Serum, Plasma, Tissue homogenate and Other biological samples

Assay Time

3.5H

Price($)

Size

Purchase details

Contact supplier to negotiate price details

100% Quality Assurance

Fast Shipping

Product Details
Product Name in English:
Rat FNDC5(Fibronectin type Ⅲ domain-containing protein 5) ELISA Kit
Species:
Rat
Alternative Name:
FRCP2, Irisin
Uniport ID:
Q8K3V5
Assay Type:
Sandwich
Standard:
4000pg/mL
Sensitivity:
37.5 pg/mL
Detection Range:
62.5-4000pg/mL
Assay Time:
3.5H
Sample Type:
Serum, Plasma, Tissue homogenate and Other biological samples
Research:
Enzyme & Kinase;
Test Principle:
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to FNDC5. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to FNDC5. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain FNDC5, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of FNDC5 in the samples is then determined by comparing the OD of the samples to the standard curve.
Technical Data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.
Concentration OD1 OD2 Average OD Corrected
4000 2.379 2.395 2.387 2.334
2000 1.539 1.54 1.54 1.494
1000 0.865 0.868 0.867 0.82
500 0.465 0.465 0.465 0.42
250 0.245 0.247 0.246 0.2
125 0.142 0.143 0.143 0.097
62.5 0.095 0.096 0.096 0.05
0 0.045 0.045 0.045 0
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level were tested on 3 different plates, 20 replicates in each plate, respectively.
Item Intra-assay Precision Intra-assay Precision
Sample 3 3
Replicate 9 18
CV(%) 5 8
Rate of recovery
The recovery of spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type Range(%) Average Recovery(%)
Serum (n=8) 82-94 88
EDTA plasma (n=8) 97-107 102
Cell culture media (n=8) 87-99 93
Linear
Samples were spiked with high concentrations of target proteins and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Serum (n=5) EDTA plasma (n=5) Cell culture media (n=5)
1:2 Range (%) 87-95 89-103 85-97
Average (%) 91 97 86
1:4 Range (%) 80-91 89-103 95-102
Average (%) 87 95 97
1:8 Range (%) 97-103 80-92 97-105
Average (%) 99 91 104
1:16 Range (%) 95-101 88-97 87-94
Average (%) 101 93 91
Assay Procedures
Related literature
Related Products