High Sensitive ELISA Kits

High Sensitivity Mouse IL-18 (Interleukin 18) ELISA Kit
Copy Product Information

Product No

FY-HS-EM1560

Sample Type

3.5H

Assay Time

1.56-100pg/mL

Price($)

Size

Purchase details

Contact supplier to negotiate price details

100% Quality Assurance

Fast Shipping

Product Details
Product Name in English:
High Sensitivity Mouse IL-18 (Interleukin 18) ELISA Kit
Species:
FY-HS-EM1560-3
Alternative Name:
Mouse
Uniport ID:
Iboctadekin, IFN-gamma-inducing factor, IGIF, IGIFIL-1 gamma, IL18, IL-18, IL-18MGC12320, IL-1F4, IL1F4iboctadekin, IL-1g, Interferon gamma-inducing factor, interleukin 18 (interferon-gamma-inducing factor), Interleukin-1 gamma, interleukin-18
Assay Type:
P70380
Standard:
Sandwich
Sensitivity:
100pg/mL
Detection Range:
0.93 pg/mL
Assay Time:
1.56-100pg/mL
Sample Type:
3.5H
Research:
Serum, Plasma, Tissue homogenate and Other biological samples;Sample Volume=100μL
Test Principle:
This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Mouse IL-18. Samples (or Standards) and and Horseradish Peroxidase (HRP) linked antibody specific for Mouse IL-18 are added to the micro ELISA plate wells. Mouse IL-18 in samples (or standards) combines with the coated antibody and HRP linked detection antibody special to Mouse IL-18. Excess conjugate and unbound sample or standard are washed from the plate. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm. The OD value is proportional to the concentration of Mouse IL-18. You can calculate the concentration of Mouse IL-18 in the samples by comparing the OD of the samples to the standard curve.
Technical Data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.
Concentration OD1 OD2 Average OD Corrected
100 2.352 2.422 2.351 2.311
50 1.55 1.626 1.549 1.509
25 0.947 0.918 0.946 0.906
12.5 0.515 0.535 0.514 0.474
6.25 0.26 0.262 0.259 0.219
3.13 0.145 0.137 0.144 0.104
1.56 0.084 0.081 0.083 0.043
0 0.041 0.042 0.04 0
Linear
Samples were spiked with high concentrations of target proteins and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Serum (n=5) EDTA plasma (n=5) Cell culture media (n=5)
1:2 Range (%) 93-103 91-105 88-110
Average (%) 98 94 93
1:4 Range (%) 91-108 88-114 90-100
Average (%) 99 98 96
1:8 Range (%) 93-108 92-113 91-110
Average (%) 95 104 92
1:16 Range (%) 89-112 91-104 93-114
Average (%) 104 91 114
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level were tested on 3 different plates, 20 replicates in each plate, respectively.
Item Intra-assay Precision Intra-assay Precision
Sample 3 3
Replicate 9 18
CV(%) 5 8
Rate of recovery
The recovery of spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type Range(%) Average Recovery(%)
Serum (n=8) 93-102 101
EDTA plasma (n=8) 89-107 102
Cell culture media (n=8) 92-111 105
Assay Procedures
Related literature