大鼠ELISA试剂盒

大鼠补体组分1Q受体1(C1qR1)酶联免疫吸附测定试剂盒
复制

货号

FY-EH4872

样本类型

Serum, Plasma, Tissue homogenate and Other biological samples;Sample Volume=100μL

检测时间

3.5H

价格(美元)

规格

采购详情

Contact supplier to negotiate price details

100% Quality Assurance

Fast Shipping

产品详情
英文名称:
Rat C1qR1( Complement Component 1q Receptor 1) ELISA Kit
种属:
Rat
别称:
C1qR1
Uniport ID:
Q9ET61
检测方法:
Sandwich
标准品:
10ng/mL
灵敏度:
0.05 ng/mL
检测范围:
0.16-10ng/mL
反应时间:
3.5H
样品类型:
Serum, Plasma, Tissue homogenate and Other biological samples;Sample Volume=100μL
测试原理:
This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Rat C1qR1 .Standards or samples are added to the micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat C1qR1 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat C1qR1 ,biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of Rat C1qR1 You can calculate the concentration of Rat C1qR1 in the samples by comparing the OD of the samples to the standard curve.
技术数据
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.
Concentration OD1 OD2 Average OD Corrected
10 2.652 2.669 2.661 2.615
5 1.728 1.74 1.734 1.691
2.5 0.92 0.928 0.924 0.883
1.25 0.393 0.394 0.394 0.356
0.63 0.182 0.183 0.183 0.145
0.32 0.0936 0.094 0.094 0.0566
0.16 0.0602 0.061 0.061 0.0232
0 0.037 0.037 0.037 0
线性
Samples were spiked with high concentrations of target proteins and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Serum (n=5) EDTA plasma (n=5) Cell culture media (n=5)
1:2 Range (%) 80-97 90-103 92-101
Average (%) 94 95 98
1:4 Range (%) 86-92 90-103 95-106
Average (%) 90 91 101
1:8 Range (%) 81-93 97-106 85-104
Average (%) 81 103 91
1:16 Range (%) 89-97 82-90 90-98
Average (%) 92 89 91
精密度
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level were tested on 3 different plates, 20 replicates in each plate, respectively.
Item Intra-assay Precision Intra-assay Precision
Sample 3 3
Replicate 9 18
CV(%) 5 8
回收率
The recovery of spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type Range(%) Average Recovery(%)
Serum (n=8) 83-99 95
EDTA plasma (n=8) 85-97 91
Cell culture media (n=8) 97-105 101
检测流程图